| Specification |
 |
¡¡ Specification Top |
¡¡ Installation |
The performance of the Welco
thermal cut-offs requires proper
handling during installation for it
to operate in its intended manner. |
|
¡¡ WEL Series |
For the HVAC manufacturer...
Mounted Thermal Cut-Offs |
|
|
|
| WEL Series |
 |
For the HVAC manufacturer...
Mounted in an insulating ceramic base, a one shot, hi-limit with configurations to suit your requirements...
WEL Series Tear Drop Style
The TCO responds to temperature by interrupting an electrical circuit when the operating and /or environmental temperature exceeds the thermal rating of the fuse. This is accomplished when the organic pellet experience a phase change, allowing the spring activated contacts to permanently open the circuit.
The electrical resistance of an WEL Series thermal cut-offs is comparable to that found in an equal length of 18 gauge solid copper wire. With proper air flow, heat generation below 15 Amperes is minimal. Above 15 Amperes, the upper limit on current capacity will depend on the environment for each specific application. |
|
APPROVAL RATINGS
| Type |
Functioning Temperature
(Tf) and Tolerance |
Holding
Temperature
(Th) |
Maximum Temperature
Limit (Tm) |
Safety Approval |
| |
¡æ |
¨H |
¡æ |
¡æ |
¡æ |
|
WEL072 |
72 |
162 |
+0/-4¡æ |
65 |
115 |
UL |
WEL077 |
77 |
171 |
+0/-4¡æ |
67 |
150 |
WEL084 |
84 |
183 |
+0/-4¡æ |
76 |
115 |
WEL093 |
93 |
199 |
+0/-6¡æ |
85 |
315 |
WEL100 |
100 |
212 |
+0/-4¡æ |
93 |
130 |
WEL104 |
104 |
219 |
+0/-4¡æ |
98 |
315 |
WEL109 |
109 |
228 |
+0/-4¡æ |
103 |
315 |
WEL117 |
117 |
243 |
+0/-4¡æ |
110 |
130 |
WEL121 |
121 |
250 |
+0/-6¡æ |
113 |
315 |
WEL128 |
128 |
262 |
+0/-4¡æ |
119 |
180 |
WEL141 |
141 |
286 |
+0/-6¡æ |
134 |
170 |
WEL169 |
169 |
336 |
+0/-6¡æ |
162 |
270(120V) 210(250V) |
WEL184 |
184 |
363 |
+0/-4¡æ |
174 |
210 |
WEL216 |
216 |
421 |
+0/-4¡æ |
210 |
375 |
WEL228 |
228 |
442 |
+0/-6¡æ |
210 |
260(120V) 230(250V) |
WEL240 |
240 |
464 |
+0/-6¡æ |
212 |
375 |
ELECTRICAL RATINGS
<WEL Electrical Rating>
| |
Voltage(AC) |
Resistive Current |
Inductive Current |
| |
(Vr) |
(Ir) |
(Ib) |
(Ir) |
(Ib) |
UL |
120V / 250V |
16.7A |
25A |
- |
- |
120V for only WEL139 |
|
All types except for
WEL139,WEL226,WEL230 |
*<Note>All types are RoHS compliant. |
| |
|
|
|
|
|
|
|